Back to Top

Hi, Guest!

  LOKASI :  Kota Administrasi Jakarta Timur

Bergabung Selama :

BAGIKAN :   

Bagikan :
  • Calibarator
  • Fluke 9170-A-256 Metrology Well Calibrators

Fluke 9170-A-256 Metrology Well Calibrators

Update Terakhir
:
01 / 12 / 2019
Min. Pembelian
:
1 Unit
Dilihat Sebanyak
:
7 kali

Harga

CALL
Bagikan
:

Perhatian !

Perusahaan ini terdaftar sebagai Free Member. Hindari melakukan pembayaran sebelum bertemu penjual atau melihat barang secara langsung. COD (Cash On Delivery) atau bertemu langsung dengan penjual merupakan metode transaksi aman yang kami sarankan.

Detail Fluke 9170-A-256 Metrology Well Calibrators

Specifications 9170 9171 9172 9173 Range ( at 23 ° C ambient) – 45 ° C to 140 ° C ( – 49 ° F to 284 ° F) – 30 ° C to 155 ° C ( – 22 ° F to 311 ° F) 35 ° C to 425 ° C ( 95 ° F to 797 ° F) 50 ° C to 700 ° C† ( 122 ° F to 1292 ° F) Display Accuracy ± 0.1 ° C full range ± 0.1 ° C: 35 ° C to 100 ° C ± 0.15 ° C: 100 ° C to 225 ° C ± 0.2 ° C: 225 ° C to 425 ° C 7nbsp; ± 0.2 ° C: 50 ° C to 425 ° C ± 0.25 ° C: 425 ° C to 660 ° C Stability ± 0.005 ° C full range ± 0.005 ° C: 35 ° C to 100 ° C ± 0.008 ° C: 100 ° C to 225 ° C ± 0.01 ° C: 225 ° C to 425 ° C ± 0.005 ° C: 50 ° C to 100 ° C ± 0.01 ° C: 100 ° C to 425 ° C ± 0.03 ° C: 425 ° C to 700 ° C Axial Uniformity ( 60 mm) ± 0.1 ° C at – 45 ° C ± 0.04 ° C at – 35 ° C ± 0.02 ° C at 0 ° C ± 0.07 ° C at 140 ° C 7nbsp; ± 0.025 ° C at – 30 ° C ± 0.02 ° C at 0 ° C± 0.07 ° C at 155 ° C ± 0.05 ° C: 35 ° C to 100 ° C ± 0.1 ° C: 100 ° C to 225 ° C ± 0.2 ° C: 225 ° C to 425 ° C ± 0.1 ° C: 50 ° C to 100 ° C ± 0.25 ° C: 100 ° C to 425 ° C± 0.4 ° C: 425 ° C to 700 ° C Radial Uniformity ± 0.01 ° C full range ± 0.01 ° C: 35 ° C to 100 ° C ± 0.02 ° C: 100 ° C to 225 ° C ± 0.025 ° C: 225 ° C to 425 ° C ± 0.01 ° C: 50 ° C to 100 ° C ± 0.025 ° C: 100 ° C to 425 ° C ± 0.04 ° C: 425 ° C to 700 ° C Loading Effect ( with a 6.35 mm reference probe and three 6.35 mm probes) ± 0.02 ° C at – 45 ° C ± 0.005 ° C at – 35 ° C ± 0.01 ° C at 140 ° C ± 0.005 ° C at – 30 ° C ± 0.005 ° C at 0 ° C ± 0.01 ° C at 155 ° C ± 0.01 ° C full range ± 0.02 ° C at 425 ° C ± 0.04 ° C at 700 ° C Hysteresis 0.025 ° C 0.04 ° C 0.07 ° C Well Depth 160 mm ( 6.3 in) 203 mm ( 8 in) Resolution 0.001 ° C Display LCD, ° C or ° F, user-selectable Key Pad Ten key with decimal and + / - button. Function keys, menu key, and ° C / ° F key. Cooling Time 44 min: 23 ° C to – 45 ° C 19 min: 23 ° C to – 30 ° C 19 min: 140 ° C to 23 ° C 30 min: 23 ° C to – 30 ° C 25 min: 155 ° C to 23 ° C 220 min: 425 ° C to 35 ° C 100 min: 425 ° C to 100 ° C 235 min: 700 ° C to 50 ° C 153 min: 700 ° C to 100 ° C Heating Time 32 min: 23 ° C to 140 ° C 45 min: – 45 ° C to 140 ° C 44 min: 23 ° C to 155 ° C 56 min: – 30 ° C to 155 ° C 27 min: 35 ° C to 425 ° C 46 min: 50 ° C to 700 ° C Size ( HxWxD) 366 x 203 x 323 mm ( 14.4 x 8 x 12.7 in) Weight 14.2 kg ( 31.5 lb) 15 kg ( 33 lb) 13.2 kg ( 29 lb) 15 kg ( 33 lb) Power 115 V ac ( ± 10 % ) , or 230 V ac ( ± 10 % ) , 50/ 60 Hz, 550 W 115 V ac ( ± 10 % ) , or 230 V ac ( ± 10 % ) , 50/ 60 Hz, 1025 W Computer Interface RS-232 Interface with 9930 Interface-it control software included Traceable Calibration ( NIST) Data at – 45 ° C, 0 ° C, 50 ° C, 100 ° C, and 140 ° C Data at – 30 ° C, 0 ° C, 50 ° C, 100 ° C, and 155 ° C Data at 100 ° C, 150 ° C, 250 ° C, 350 ° C, and 425 ° C Data at 100 ° C, 200 ° C, 350 ° C, 500 ° C, and 660 ° C † Calibrated to 660 ° C; reference thermometer recommended at higher temperatures. Specifications Built-in Reference Input Temperature Range – 200 ° C to 962 ° C ( – 328 ° F to 1764 ° F) Resistance Range 0 & to 400 & , auto-ranging Characterizations ITS-90 subranges 4, 6, 7, 8, 9, 10, and 11 Callendar-Van Dusen ( CVD) : R0, a, b, d Resistance Accuracy 0 & to 20 & : 0.0005 W 20 & to 400 & : 25 ppm Temperature Accuracy ( does not include probe uncertainty) 10 & PRTs: ± 0.013 ° C at 0 ° C ± 0.014 ° C at 155 ° C ± 0.019 ° C at 425 ° C ± 0.028 ° C at 700 ° C 25 & and 100 & PRTs: ± 0.005 ° C at – 100 ° C ± 0.007 ° C at 0 ° C ± 0.011 ° C at 155 ° C ± 0.013 ° C at 225 ° C ± 0.019 ° C at 425 ° C ± 0.027 ° C at 661 ° C Resistance Resolution 0 & to 20 & : 0.0001 & 20 & to 400 & : 0.001 & Measurement Period 1 second Probe Connection 4-wire with shield, 5-pin DIN connector Calibration NVLAP accredited ( built-in reference input only) , NIST-traceable calibration provided
Tampilkan Lebih Banyak