Back to Top

Hi, Guest!

  LOKASI :  Kota Administrasi Jakarta Timur

Bergabung Selama :

BAGIKAN :   

Bagikan :

HACH DR 5000 UV/ VIS SPECTRO METER

Update Terakhir
:
01 / 12 / 2019
Min. Pembelian
:
1 Unit
Dilihat Sebanyak
:
45 kali

Harga

CALL
Bagikan
:

Perhatian !

Perusahaan ini terdaftar sebagai Free Member. Hindari melakukan pembayaran sebelum bertemu penjual atau melihat barang secara langsung. COD (Cash On Delivery) atau bertemu langsung dengan penjual merupakan metode transaksi aman yang kami sarankan.

Detail HACH DR 5000 UV/ VIS SPECTRO METER

Maximum analysis flexibility with high speed wavelength scanning across the UV and visible spectrum Easily Add New Analytical Methods Stability and Accuracy Multiple Cell Sizes and Delivery Methods Large Touch Screen Display and Interface Maximum analysis flexibility with high speed wavelength scanning across the UV and visible spectrum The Hach DR 5000 UV-Vis Laboratory Spectrophotometer can test for all of the parameters listed on page 3. All of the chemistries and supplies needed for these tests are available from Hach. Easily Add New Analytical Methods As Hach releases new test methods and chemistries, the DR 5000 spectrophotometer can easily be updated via a USB memory stick. Stability and Accuracy The design of the DR 5000 spectrophotometer ensures measurements are accurate, precise, and stable over time, resulting in repeatable results. Multiple Cell Sizes and Delivery Methods A single multi-cell adapter for the DR 5000 spectrophotometer holds the five most common sample cell types, including 5 cm path length cells. Moreover, the optional Pour-Thru™ Cell Module is ideal for Rapid Liquid™ methods. Large Touch Screen Display and Interface The touch screen display of the DR 5000 spectrophotometer is intuitive to use and ergonomic in design. Accessories: Sipper Module DR 5000 LZV485 Peltier temperature controlled Module DR 5000 LZV513 Pour-Thru Module, 1 inch, LZV479 Pour-Thru Module, 1 cm, LZV789 Multi-Cell Holder DR 5000 A23618 Carousel Holder ( Sample changer) LZV478 USB-Keyboard ( keyboard layout: US) LZV582 USB-Barcode Scanner ( handset scanner) LZV566 Hach Data Trans ( PC software for data transfer) LZY274 Brewery Analysis Software LZV659 Tubing Inlet Sipper DR 5000 ( PHARMED) for Drinkingwater Applications LZV580 Standard Sipper Tubing LZV780 Pour Thru Tube Kit LZV569 USB Memory Stick 2946900 USB Extension Cable, ( 1 m) LZV567 Tungsten ( VIS) Lamp A23778 Deuterium ( UV) Lamp A23792 Fuse A23772 Filter Pad A23766 Certified test filter set for self-checks ( Verification Kit) ( 6 precision glass filters with target values) LZV537 Semi-Micro Cell, Glass, 50 mm LZP269 Sample Cell, Glass, 20 mm LZP331 Sample Cell, 1 cm Square Glass, ( 10 mm path length) matched pair 2095100 Sample Cell, 1 cm Square Quartz, ( 10 mm path length) matched pair 4822800 Sample Cell, 50 mm Rectangular Glass 2629250 Sample Cell, 50 mm Rectangular Quartz 2624450 Sample Cell, 100 mm Rectangular Glass 2629201 Sample Cell, 100 mm Rectangular Quartz 2624401 Sample Cell, 1 Round Plastic, ( 1 cm path length) 10 mL, w/ cap 4864302 Sample Cell, 1 Square Glass, 10 mL, matched sets 2495402 Sample Cell, 1 Square Glass, 10& 25 mL, matched sets 2665902 Sample Cell, 1 Square Plastic, pk/ 12 2410212 Pour Thru Cell, 1x1 cm ( Quartz/ 160 ¼ L/ glass center height 10 mm) A24209 Pour Thru Cell, 1x1 cm ( Quartz/ 450 ¼ L/ glass center height 10 mm) LZV510 Pour Thru Cell, 5x1 cm ( Quartz/ 370 ¼ L/ glass center height 10 mm) LZV649 Pour Thru Cell, 1 Square ( 1 path length) 5913700 Adapter for 100 mm Sample Cell LZY421 Dust Cover LZV728 Beam Height: 10 mm Data Logger: 1000 Points Data Storage: 1000 points Dimensions ( H x W x D) : 7.9 in x 17.7 in x 19.7 in ( 200 mm x 450 mm x 500 mm) Display: Backlit Grayscale LCD Touch Screen Display Resolution: 320 pixels x 240 pixels minimal Display Size: 115.7 mm x 88.7 mm Display Type: Backlit Enclosure Rating: IP31 Includes: 115 and 230V power cords, printed user manual, CD procedures manual, matched pair of 1 inch glass sample cells, matched pair of 1 cm quartz sample cells, multi-cell holder Interfaces: 2 x USB type A; 1 x USB type B ( 10 ft ( 3 m) cable, maximum) Mains Connection 2: 200 V - 240 V Mains Connection 3: 50 / 60 Hz automatic changeover Manual Languages: English German French Italian Spanish Dutch Danish Polish Swedish Turkish Gr eek Romanian Hungarian Portuguese Czech Slovenian Russian Serbian Bulgarian English - USA French - Canada Spanish - SA Portuguese - Brasilian Chinese Japanese Korean Max. operating humidity: 80 Max. Storage Humidity: 80 Operating Mode: Transmittance ( % ) , Absorbance and Concentration Operating Temperature Range: 10 to 40 ° C at 95% Relative Humidity ( non-condensing) Optical System: Split Beam Photometric Accuracy: 5 mAbs at 0.0-0.5 Abs Photometric Accuracy 2: 1 % at 0.50-2.0 Abs Photometric Linearity: 2 Abs Photometric Measuring Range: ± 3 Abs in the wavelength range 200 to 900 nm Power Requirements: 100 V - 120 V Power Requirements ( Hz) : 50 - 60 Hz Power Requirements ( Voltage) : 100 - 240 V AC Sample Cell Compatibility: 1-in. square; 1-in. round; 1x1, 2x1, 5x1, 10x1 cm; 13 mm round; 16 mm round; 1 cm, 5 cm, and 1-in. Pour-Thru Cells; AccuVac Ampules Scanning Speed: 900 nm/ min in 1 nm steps; 1 complete scan/ 1 min Source Lamp: Tungsten ( VIS) and Deuterium ( UV) Spectral Bandwidth: 2 nm Storage Conditions: -40 ° C to 60 ° C ; 80% Relative Humidity Stray Light: KI-solution at 220 nm > 3.3 Abs or < 0.05% User Interface Languages: Chinese, English, French, Japanese, Korean, Brazilian Portuguese, Spanish ( Please contact your Hach representative for availability of additional languages.) User Programs: 50 Warranty: 12 months Wavelength Accuracy: ± 1 nm in wavelength range 200 to 900 nm Wavelength Calibration: Automatic Wavelength Range: 190 to 1100 nm Wavelength Resolution: 0.1 nm Wavelength Selection: Automatic: based on selected program method Automatic: based on barcode printed on TNTplus™ reagent vials Manual: in all modes except stored programs Weight: 34.17 lbs. ( 15.5 kg)
Tampilkan Lebih Banyak